Enter A-weighted levels and how long each lasted during a working day. The calculator returns the NIOSH and OSHA daily dose side by side — two different criteria that should never be mixed.
Use levels from a calibrated sound level meter or dosimeter. Readings from this site's browser meter are not accepted here automatically, because a phone microphone is not an occupational measuring instrument. A dose below 100% is not a guarantee that hearing is safe.
Exposure periods
Total: 8 h 0 min
Results
Recommendation · 85 dBA · 3 dB exchange
NIOSH recommended exposure limit
157.9%
of the daily dose · 8-hour TWA 87.0 dBA
0%100%158%
Above the 85 dBA 8-hour criterion.
Counts levels from 80 dBA upward (NIOSH integration threshold). NIOSH also recommends that impulsive noise never exceed 140 dBA.
US regulation · 90 dBA · 5 dB exchange
OSHA permissible exposure limit
28.7%
of the daily dose · 8-hour TWA 81.0 dBA
0%100%
At or below the 90 dBA 8-hour criterion.
Levels below 90 dBA are not counted toward the PEL (Table G-16 starts at 90 dBA).
Hearing-conservation dose (80–130 dBA counted): 60.0% — at or above the 50% action level.
Contribution of each period to the daily dose
Period
Level
Duration
NIOSH
OSHA PEL
OSHA action
1
85 dBA
4 h 0 min
50.0%
not counted
25.0%
2
91 dBA
2 h 0 min
100.0%
28.7%
28.7%
3
80 dBA
2 h 0 min
7.9%
not counted
6.3%
Recommendation versus regulation
NIOSH publishes a recommended exposure limit of 85 dBA as an 8-hour time-weighted average with a 3 dB exchange rate: every 3 dB increase halves the reference time. It is a research-based recommendation, not a law.
OSHA enforces a permissible exposure limit of 90 dBA over 8 hours with a 5 dB exchange rate in US general industry. A separate action level — an 8-hour TWA of 85 dBA, or a 50% dose with levels from 80 to 130 dBA counted — triggers a hearing conservation program. The same day can therefore exceed the NIOSH recommendation while staying within the OSHA PEL, as the worked example shows.
Neither figure is a threshold below which hearing is guaranteed safe. Individual susceptibility, impulse noise and measurement uncertainty all matter.
Three different numbers: threshold, criterion and action limit
Thresholds and criteria used by each dose
Dose
Measurement threshold
Criterion level (100%)
Limit that triggers action
NIOSH REL
80 dBA
85 dBA for 8 h, 3 dB exchange
Dose above 100% exceeds the recommendation
OSHA PEL
90 dBA
90 dBA for 8 h, 5 dB exchange
Dose above 100% exceeds the legal limit
OSHA action level
80 dBA
90 dBA for 8 h, 5 dB exchange
Dose of 50% (TWA 85 dBA) requires a hearing conservation program
The measurement threshold decides which levels are counted at all. The criterion level is the level that gives a 100% dose over 8 hours. The action limit is the dose at which a rule or recommendation applies. Both OSHA doses use the same 90 dBA criterion and 5 dB exchange; they differ only in which levels are counted and which percentage matters.
Method
Dose: D = 100 × (C₁/T₁ + C₂/T₂ + …), where C is the time spent at a level and T the reference duration for it.
NIOSH reference duration: T = 480 / 2^((L − 85)/3) minutes. TWA = 10 × log₁₀(D/100) + 85.
OSHA reference duration: T = 8 / 2^((L − 90)/5) hours. TWA = 16.61 × log₁₀(D/100) + 90.
Limitations: each period is treated as one steady A-weighted level. Real dosimeters integrate continuously with slow time response; this calculator cannot account for fluctuation within a period, impulse or peak noise, hearing protection, or measurement uncertainty. NIOSH counts 80–140 dBA, OSHA PEL from 90 dBA, OSHA action dose 80–130 dBA.
Worked example
Four hours at 85 dBA, two hours at 91 dBA and two hours at 80 dBA. NIOSH: 50% + 100% + 7.9% = 157.9%, a TWA of about 87.0 dBA — above the recommendation. OSHA PEL: the 90 dBA threshold excludes the 85 and 80 dBA periods, so only 2 h at 91 dBA counts: 120 min ÷ 417.8 min = 28.7%, a TWA of about 81.0 dBA — within the PEL. OSHA action level: the 80 dBA threshold counts all three periods with the same OSHA formula: 25.0% (4 h at 85 dBA, T = 16 h) + 28.7% + 6.25% (2 h at 80 dBA, T = 32 h) = 60.0%. That is above the 50% action limit, so a hearing conservation program would be required.